back to all Isolation

Single Convoluted - Airspring Isolators

17 Styles

See Imperial Units
Load Rating % Isolation at Forced Freq.
Style Number Design Height (mm) 3 Bar (Kn) 5 Bar (Kn) 7 Bar (mm) Nat. Freq.@ 7 Bar 7 Hz 13 Hz 25 Hz
16 76 2 3.4 5 3.9 90.3 97.4
131 89 2.7 4.6 6.6 2 74.4 94.6 98.5
160 115 3.7 6 8.3 2.6 89.4 97.5 99.3
110 114 3.1 5.4 7.8 2.6 80.2 95.7 98.8
116 114 4.1 7.2 10.3 2.3 80.2 95.7 98.8
116-1 140 4.5 7.6 10.9 2.6 86.3 96.9 99.1
115 114 5.7 9.4 13.3 2.5 83.4 96.3 99
19 127 10.3 17.8 25.4 2.5 78.6 95.4 98.7
19.75 140 9.1 15.9 23 2.3 82 96 89.9
113 127 15.6 27.1 38.9 2.2 83.1 96.3 99
113-1 140 18.5 31.8 45.1 2 87.7 97.2 99.2
153-2 150 22.4 39 56.6 2.3 89.9 97.7 99.3
119 127 26.6 45.5 64.6 2.2 86.5 96.9 99.1
121 127 31.2 55.4 81.6 2.3 85.5 96.7 99.1
126 127 53.4 89.9 126.8 2.2 86.3 96.9 99.1
138-1.5 152 76.8 131.8 158.7 1.9 89.9 97.7 99.3
148-1 140 159 270 382.1 2 90.5 97.8 99.4

Data by Sleeve Type

Select a Sleeve Type to see Product Data

How Can We Help You?

Please contact us for more information on how to improve the comfort of your ride.

Contact Us